5. Install all components removed from the failed system board.
6. Connect all cables.
7. Install the access panel.
8. Install the server into the rack.
9. Connect all peripheral cables to the server.
10. Connect each power cord to the server.
11. Connect each power cord to the power source.
12. Power up the server.
13. Ensure all firmware, including option cards and embedded devices, is updated to the same versions to ensure that the latest drivers are
being used.
14. Re-enter any Secure Boot Keys that were previously added in the Secure Boot configuration.
15. If Intel Xeon Gold 6244 Processors are installed, enable the enhanced cooling function .
16. If removed, install the front bezel.
17. Re-enter the server serial number and product ID
Re-entering the server serial number and product IDRe-entering the server serial number and product ID
About this taskAbout this task
After replacing the system board, re-enter the system serial number and product ID, and configure the date and time settings.
ProcedureProcedure
1. Access the UEFI System Utilities. During POST, press F9F9.
2. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options > Advanced
Service Options.
3. Select Serial Number, and then press EnterEnter.
The following warning appears:
4. Click OK.
5. Type the serial number, and then press EnterEnter.
6. Select Product ID, and then press EnterEnter.
The following warning appears:
7. Type the product ID, and then press EnterEnter.
8. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Date and Time.
9. Configure the date and time settings:
Date (mm-dd-yyyy)—Enter the date in a month-day-year (mm-dd-yyyy) format.