HPE ProLiant DL160 Gen10 - Results; Removing and replacing a fan blank; About this task; Procedure

HPE ProLiant DL160 Gen10
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CAUTION:CAUTION: The fan does not have a fan guard. Special attention is needed when removing or installing the fan to
prevent finger injury.
ResultsResults
To replace the component, reverse the removal procedure.
Removing and replacing a fan blankRemoving and replacing a fan blank
About this taskAbout this task
CAUTION:CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a
component or a blank.
ProcedureProcedure
1. Back up all server data.
2. If installed, remove the front bezel .
3. Power down the server.
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Disconnect all peripheral cables from the server.
6. Do one of the following:
Extend the server from the rack .
Remove the server from the rack .
HPE ProLiant DL160 Gen10 Server Maintenance and Service Guide 57