Step 2 Power off the server. For details, see 3.2 Powering Off the Server.
Step 3 Remove the power cables. For details, see 3.7 Removing Cables from a PSU.
Step 4 Remove the server. For details, see 3.3 Removing the Server and Guide Rails.
Step 5 Remove the chassis cover. For details, see 3.4 Removing the Chassis Cover.
Step 6 Remove the riser card tray where the RAID controller card is to be installed. For details, see
3.12 Removing a Riser Card Tray.
Step 7 Take a spare Avago SAS3004iMR RAID controller card out of the ESD bag.
Step 8 Install the Avago SAS3004iMR RAID controller card. For details, see 5.5 PCIe Card on a
Riser Card.
Step 9 Install the riser card tray. For details, see 3.13 Installing a Riser Card Tray.
Step 10 Install the M.2 SSD modules on the Avago SAS3004iMR RAID controller card. For details,
see 5.10 M.2 SSD Module.
Step 11 Install the chassis cover. For details, see 3.5 Installing the Chassis Cover.
Step 12 Install the server. For details, see 4.4 Installing the Server on Guide Rails.
Step 13 Connect the power cables. For details, see 5.4 PSU.
Step 14 Power on the server. For details, see 3.1 Powering On the Server.
Step 15 Log in to the iBMC WebUI, and check whether the new component is normal. For details, see
the Huawei Rack Server iBMC User Guide.
----End
5.10 M.2 SSD Module
To install an M.2 SSD module, perform the following steps:
Step 1 Wear an ESD wrist strap. For details, see 12 Preventing Electrostatic Discharge.
NOTE
M.2 SSD modules support hot swap. You do not need to power off the server when installing an M.2
SSD module.
Step 2 Take an M.2 SSD module out of its ESD bag.
Step 3 Open the handle that secures the M.2 SSD module, push the module into a slot in the Avago
SAS3004iMR RAID controller card, and close the handle. See Figure 5-35.
2288H V5 Server
User Guide
5 Optional Part Installation