Figure 5-35 Installing an M.2 SSD module
Step 4 Log in to the iBMC WebUI, and check whether the new component is normal. For details, see
the Huawei Rack Server iBMC User Guide.
----End
5.11 Supercapacitor
To install a supercapacitor, perform the following steps:
Step 1 Wear an ESD wrist strap. For details, see 12 Preventing Electrostatic Discharge.
NOTE
Before installing a supercapacitor, power off the server for electrical safety.
Step 2 Power off the server. For details, see 3.2 Powering Off the Server.
Step 3 Remove the power cables. For details, see 3.7 Removing Cables from a PSU.
Step 4 Remove the server. For details, see 3.3 Removing the Server and Guide Rails.
Step 5 Remove the chassis cover. For details, see 3.4 Removing the Chassis Cover.
Step 6 Take a spare supercapacitor out of its ESD bag.
Step 7 Place the supercapacitor downwards and exert even force to install it in the tray. Ensure that
the supercapacitor is secured by the latches. See Figure 5-36.