Step 13 Install the chassis cover. For details, see 3.5 Installing the Chassis Cover.
Step 14 Install the server. For details, see 4.4 Installing the Server on Guide Rails.
Step 15 Connect the power cables. For details, see 5.4 PSU.
Step 16 Power on the server. For details, see 3.1 Powering On the Server.
----End
5.18 Right Mounting Ear
To install the right mounting ear, perform the following steps:
Step 1 Wear an ESD wrist strap. For details, see 12 Preventing Electrostatic Discharge.
Step 2 Power off the server. For details, see 3.2 Powering Off the Server.
Step 3 Remove the power cables. For details, see 3.7 Removing Cables from a PSU.
Step 4 Remove the server. For details, see 3.3 Removing the Server and Guide Rails.
Step 5 Remove the chassis cover. For details, see 3.4 Removing the Chassis Cover.
Step 6 Remove the air duct or the built-in drive assembly. For details, see 3.8 Removing the Air
Duct or 3.10 Removing the Built-in Drive Assembly.
Step 7 Take a spare right mounting ear out of its ESD bag.
Step 8 Route the mounting ear signal cable through the chassis in the arrow direction. See (1) in
Figure 5-62.