Interface Numbering
An interface is numbered in the format of slot number/subcard number/port number.
Slot number: The slots of LPUs are numbered from top to bottom and from left to right (marked on the
panel), in the range of 1 to 8.
Subcard number: The subcards are numbered from top to bottom and from left to right, starting from 0.
If an LPU does not have any subcard, the subcard number is 0.
Port number: The ports are numbered from top to bottom and from left to right, starting from 0.
Technical Specifications
(21 U) 930 mm x 442 mm x 650 mm (36.61 in. x
17.40 in. x 25.59 in.) (Chassis main body)
(21 U) 930 mm x 442 mm x 750 mm (36.61 in. x
17.40 in. x 29.53 in.) (Dimensions of the chassis
body together with cable trays and front and back
attachments)
DC: 68.1 kg (150.16 lb) (without filler panels)
HVDC&AC: 63.7 kg (140.46 lb) (without filler
panels)
Weight (full configuration)
[400G bundle] DC:186.1 kg (410.35 lb)
[400G bundle] HVDC&AC:184.3 kg (406.38 lb)
[1T bundle] DC:209 kg (460.85 lb)
[1T bundle]HVDC&AC:206.5 kg (455.33 lb)
Cabinet installation standard
Can be installed in a standard 19" 800 mm-deep
cabinet. A Huawei 2.2 m-high N68E cabinet is used by
default.
Typical power consumption
4110 W (fully configured with LPUF-240s)
4770 W (fully configured with LPUF-480s)
6520 W (fully configured with LPUI-1Ts)