EasyManua.ls Logo

Huawei NE40E - Ac Pm

Huawei NE40E
1058 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware Description
1 Hardware Description
Issue 01 (2018-05-03)
162
Note the derating requirements of protection components when using protection components
such as fuses and circuit breakers. If the current of a PDF is less than 63 A, it cannot supply
power to the NE40E-X16A. In this case, reconstruct power supply in the equipment room.
If the front-end PDF does not provide enough power inputs, configure a PDB that meets
the following requirements:
The current of each channel output by the DC PDB is not less than 63 A.
Double-channel backup is used.
The input current is not less than the sum of current of its connected output lines.
1.8.6.5 2700 W AC PM
The PM accesses external AC power through PEMs, the PMs convert AC power into
regulated DC power and output the power to the power supply backplane.
Overview
Table 1-83 Power attributes
Attribute
Description
Description
2700W AC Power module
BOM
02310SHP
Model
PAC-2700WB
Table 1-84 Mapping products and versions
Product
Earliest Software Version
NE40E-X8A
V800R006C10
NE40E-X16A
V800R006C10
Appearance
Figure 1-66 shows the appearance of a AC PM module.

Table of Contents

Related product manuals