Hardware Description
1 Hardware Description
Issue 01 (2018-05-03)
284
Panel
Table 1-268 Buttons
Name
Description
OFL
Before removing a board, press and hold the OFL button for about 6
seconds until the OFL indicator turns on. Then, you can remove the
board.
Table 1-269 Indicators
Name
Description
RUN
Before the board registration: The green indicator blinks twice every
second (2 Hz).
After the registration of the board: If the green indicator blinks once
every two seconds (0.5 Hz), the system is working properly.
OFL
If the red indicator is off, the board is working properly. If the red
indicator is on, the board is powered off.
Functional Specifications
Table 1-270 Functions and features
Functions and
Features
Remarks
Reliability and
availability
The 3+1 backup mode is used. The four SFUs balance services at the
same time. If one SFU is faulty or replaced, the other three SFUs
automatically take over its services to prevent service interruptions.
Technical Specifications
Table 1-271 Board specifications
Item
Specification
Dimensions (H x W x D)
40.1 mm x 409.3 mm x 534.3 mm (1.58 in. x 16.11 in. x
21.04 in.)
Typical power
consumption
270.0 W
Typical heat dissipation
876.0 BTU/hour
Weight
9.5 kg (20.95 lb)