EasyManuals Logo

Huawei SUN2000-3KTL-M1 User Manual

Huawei SUN2000-3KTL-M1
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
Parameter Name Description
Power control
hysteresis
Species the dead zone for adjusting
the SUN2000 output power. If the
power uctuation is within the power
control hysteresis, the power is not
adjusted.
Active power output
limit for fail-safe
Species the derating value of the
SUN2000 active power by percentage.
If the Smart Dongle does not detect
any meter data or the
communication between the Smart
Dongle and the SUN2000 is
disconnected, the Smart Dongle
delivers the derating value of the
SUN2000 active power by percentage.
Communication
disconnection fail-safe
In the SUN2000 anti-backfeeding
scenario, if this parameter is set to
Enable, the SUN2000 will derate
according to the active power
derating percentage when the
communication between the
SUN2000 and the Smart Dongle is
disconnected for a period longer than
Communication disconnection
detection time.
Communication
disconnection
detection time
Species the time for determining the
communication disconnection
between the SUN2000 and the
Dongle.
This parameter is displayed when
Communication disconnection fail-
safe is set to Enable.
----End
7.2.1.2 Battery Control
Prerequisites
The screenshots in this chapter are taken in the SUN2000 3.2.00.011 app. The app
is being updated. The actual screens prevail.
Function
When the inverter connects to a battery, add the battery and set battery
parameters.
SUN2000-(3KTL-10KTL)-M1
User Manual 7 Man-Machine Interaction
Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 76

Table of Contents

Other manuals for Huawei SUN2000-3KTL-M1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-3KTL-M1 and is the answer not in the manual?

Huawei SUN2000-3KTL-M1 Specifications

General IconGeneral
ModelSUN2000-3KTL-M1
TypeString Inverter
Max. DC Input Voltage600 V
MPPT Voltage Range90 V - 560 V
Rated AC Output Power3000 W
Max. AC Output Power3300 W
Nominal AC Voltage220 V / 230 V / 240 V
AC Voltage Range180 V - 280 V
AC Output Frequency50 Hz / 60 Hz
Max. Efficiency98.6%
MPPT Trackers2
DC Inputs per MPPT1
Max. Input Current per MPPT11 A
Operating Temperature Range-25°C to +60°C
Cooling MethodNatural Convection
Protection DegreeIP65
Max. DC Input Power4500 W
CommunicationRS485
Dimensions (W x H x D)365 mm x 365 mm x 156 mm