3–Operation
ERR 6 LOWER LIM DURING OPR The lifter reached the lower limit during operation.
ERR 7 FAILED MOVE TO IHS START The lifter failed to reach IHS Start Height.
ERR 8 FAILED TO CONTACT PLATE The torch failed to contact the workpiece within 60 seconds.
ERR 9 FAILED TO CLEAR PLATE The torch failed to retract and break ohmic contact within 10 seconds.
ERR 10 FAILED TO MOVE TO XFER HT The torch failed to retract to Transfer Height within 10 seconds.
ERR 11 IHS SYNC TIMEOUT The torch reached the IHS position but IHS SYNC was not released within
60 seconds.
ERR 12 TRANSFER TIMEOUT The Transfer signal was not received from the plasma system within
60 seconds.
ERR 13 LOST TRANSFER The plasma arc was lost during the cut.
ERR 14 FAILED MOVE TO PIERCE The lifter failed to reach Pierce Start Height within 10 seconds.
ERR 15 FAILED MOVE CUTHEIGHT The lifter failed to reach Cut Height during Accel Delay.
ERR 16 RAMPDOWN TIMEOUT The Motion signal was not removed within 10 seconds.
ERR 17 RETRACT TIMEOUT The lifter failed to retract within 20 seconds at the end of the cut.
ERR 18 ERR SAMPLED ARC VOLTS During the sample arc voltage operation, there was an excessive
change in sample voltage.
ERR 19 EXCESS PLATE CONTACT During the cut, the torch made excessive contact with the
workpiece.
ERR 20 PLASMA SUPPLY Plasma system error.
ERR 21 OHMIC TIP SENSE Nozzle Contact Sense was enabled but not sensed.
Critical Errors
ERR 23 INPUT VOLTAGE LOW The incoming AC line voltage is more than 20% low.
ERR 24 INPUT VOLTAGE HIGH The incoming AC line voltage is more than 15% high.
ERR 25 OVER-TEMPERATURE The temperature of the processor has exceeded the maximum value.
ERR 26 MOTOR DRIVE The temperature for the motor drive has exceeded the maximum value.
ERR 27 INTERLOCK TRIPPED The safety interlock was removed.
ERR 28 BREAKAWAY TRIPPED The torch breakaway was removed.
ERR 29 FIELD SUPPLY FAILED The +5 V, +12 V, or -12 V supply has failed.
ERR 30 STALL CALIBRATION Stall Calibration down motion failed after power was turned ON.

Table of Contents

Other manuals for Hypertherm ArcGlide THC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm ArcGlide THC and is the answer not in the manual?

Hypertherm ArcGlide THC Specifications

General IconGeneral
BrandHypertherm
ModelArcGlide THC
CategoryControl Systems
LanguageEnglish

Related product manuals