InstallatIon
3-60  HPR800XD Auto Gas  –  806500
Fill the chiller with coolant
See the chiller operators manual for details
Caution:  Using the wrong coolant can cause damage to the system. Refer to torch 
coolant requirements in this section for more information.
Do not over fill the coolant tank.
Caution:  Do not turn ON the power to the controller until the chiller reservoir has been 
filled. When the power to the controller is turned ON the pump automatically 
begins pumping. If the reservoir has not been filled, the pump could be 
damaged.
Caution:  The first time the chiller is operated it should be run overnight in the 
standby mode. The compressor crankcase heater will boil off any refrigerant 
absorbed in the compressor oil.