InstallatIon
3-28 HPR800XD Auto Gas 806500
8
Chiller interface power cable
Cable signal list – primary power supply to chiller interface
Power supply end Chiller interface end
Pin No.
Wire
color
Description Pin No.
1
Red/
black
240 VAC-hot 1
2 Red 240 VAC-return 2
3 Shield Ground 3
15 White Solenoid V1- return 15
11 Black Solenoid V1- hot 11
6 Shield Ground 6
Part no. Length
123979 1.5 m (5 ft)
123980 3 m (10 ft)
123981 4.5 m (15 ft)
Primary power supply to chiller interface console
8
End with sockets to
chiller interface
Note: The inductor on the pump motor drive board makes a noise during operation that has been
described as a “hum”, “sing”, and “click”. This is normal and can be disregarded.

Table of Contents