OperatiOn
4-54 HPR800XD Auto Gas – 806500
Mild steel
O
2
Plasma / Air Shield
260 A
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
mm Volts mm mm/m mm Factor % Seconds
O
2
Air 22 49
76 46
6
150 2.8
6500
8.5 300
0.38 5470
10 4440
12 3850 0.4
80
49
15 155
3.6
3130
9.0 250
0.5
20 159 2170 0.6
22 166 1930 0.7
84
25 171 1685 0.8
28 170
4.8
1445
9.5 200
0.9
32 172 1135 1.0
38 174 895
Edge start
44 185 580
50 188 405
58 193 290
64 202 195
Metric
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
in Volts in ipm in Factor % Seconds
O
2
Air 22 49
76 46
1/4
150 0.11
245
0.33 300
0.35/16 215
3/8 180
1/2 145 0.4
80
49
5/8 155
0.14
115
0.35 250
0.5
3/4 159 90 0.6
7/8 166 75 0.7
84
1 171 65 0.8
1-1/8 170
0.19
55
0.38 200
0.9
1-1/4 172 45 1.0
1-1/2 174 35
Edge start
1-3/4 185 22
2 188 15
2-1/4 193 12
2-1/2 202 8
English
Flow rates – lpm/scfh
O
2
Air
Preflow 0 / 0 130 / 275
Cutflow 42 / 88 104 / 220
220764220637 220760 220436220439 220340220435
Marking
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps mm in mm/m ipm Volts
N
2
N
2
10 10 10 10 18 2.5 0.10 6350 250 135
Ar Air 30 20 30 20 24 3.0 0.12 2540 100 68