OperatiOn
HPR800XD Auto Gas – 806500 4-75
Stainless steel
H35 Plasma / N
2
Shield
260 A
Flow rates – lpm/scfh
H35 N
2
Preflow 0 / 0 127 / 270
Cutflow 40 / 84 122 / 260
Marking
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps mm in mm/m ipm Volts
N
2
N
2
10 10 10 10 18 2.5 0.10 6350 250 120
Ar N
2
30 10 30 10 20 3.0 0.12 2540 100 63
220763220637 220307220758 220405220406 220340
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
mm Volts mm mm/m mm Factor % Seconds
H35 N
2
12 49 85 60
8
188 11.0
2030
11.0
100
0.3
10 1870
12 173 9.0 1710
9.0
0.4
15 171
7.5
1465
120
0.5
20 175 1085 0.6
25 180 785 0.7
32 185 630 1.0
38 186 510
Edge start44 189 390
50 200 270
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
in Volts in ipm in Factor % Seconds
H35 N
2
12 49 85 60
5/16
188 0.45
80
0.45
100
0.3
3/8 75
1/2 173 0.35 65 0.35 0.4
5/8 171
0.30
55
0.36 120
0.5
3/4 175 45 0.6
1 180 30 0.7
1-1/4 185 25 1.0
1-1/2 186 20
Edge start1-3/4 189 15
2 200 10