EasyManua.ls Logo

Hypertherm HyPerformance Plasma HPR800XD - Page 193

Hypertherm HyPerformance Plasma HPR800XD
366 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OperatiOn
HPR800XD Auto Gas 806500 4-87
Stainless steel
H35 Plasma / N
2
Shield
600 A
220707220637 220709220635 220353220859 220571
Flow rates – lpm/scfh
H35 N
2
Preflow 0 / 0 113 / 240
Cutflow 76 / 160 134 / 283
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
mm Volts mm mm/m mm Factor % Seconds
H35 N
2
43 13
78
43
40 189
12.7
721
25.4 200
2.0
45 194 677 2.5
50 197 597 3.0
60 201 492
Edge start
80 222 19.1 307
68 100 212 10.2 187
Metric
Marking
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
in Volts in ipm in Factor % Seconds
H35 N
2
43 13
78
43
1-1/2 189
0.50
29
1.0 200
2.0
1-3/4 194 27 2.5
2.0 197 23 3.0
2-1/2 201 18
Edge start
3.0 222 0.75 13
68 4.0 212 0.40 7
English
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps mm in mm/m ipm Volts
N
2
N
2
50 20 50 20 24 6.4 0.25 2540 100 106
Ar N
2
50 20 50 20 25 2.5 0.1 2540 100 57
Note: Pierce complete must be turned OFF for all 600 amp processes.