Appendix B – CnC interfACe protoCol
HPR800XD Auto Gas806500 b-7
Command table (2 of 14)
ID Command System Description
028 READ_PLASMA_AMPS Manual gas system
Auto gas system
Read actual power supply current.
Data:
None
Return value:
Power supply current in amps
Sample:
>0289A<
>02801305E< (130 amps)
058 SET_NOMINAL_AMPS Auto gas system Set the power supply current in amps.
Data:
5-260 Amps (Limited to 130 amps on the HPR130)
Return value:
Actual current value set
Sample:
>05813031<
>058013061< (set 130 amps)
064 GAS_PREFLOW_TEST_START Manual gas system
Auto gas system
Turn on the preflow gases. Not allowed when cutting.
Data:
None
Return value:
1 = accepted, 0 = not accepted
Sample:
>0649A<
>0641CB<
065 GAS_PREFLOW_TEST_STOP Manual gas system
Auto gas system
Turn off the preflow gases. Not allowed when cutting.
Data:
None
Return value:
1 = accepted, 0 = not accepted
Sample:
>0659B<
>0651CC<
066 GAS_CUTFLOW_TEST_START Manual gas system
Auto gas system
Turn on the cutflow gases. Not allowed when cutting.
Data:
None
Return value:
1 = accepted, 0 = not accepted
Sample:
>0669C<
>0661CD<
067 GAS_CUTFLOW_TEST_STOP Manual gas system
Auto gas system
Turn off the cutflow gases. Not allowed when cutting.
Data:
None
Return value:
1 = accepted, 0 = not accepted
Sample:
>0679D<
>0671CE<)