Appendix B – CnC interfACe protoCol
b-18 HPR800XD Auto Gas 806500
ID Command System Description
126 GET_INFO2 Auto gas control
board only
See 079
127 GET_INFO3 Auto gas control
board only
See 079
131 CLEAR WARNINGS Manual gas system
Auto gas system
This command will clear error codes less than #43.
Sample:
>13195<
>1311C6<
132 READ COOLANT PRESSURE HPR260 ONLY This command returns the raw A/D value for coolant pressure.
83 counts = 225 psi
73 counts = 200 psi
Sample:
>13296<
>13280FE<
133 GET CONTROL DATA3 HPR400XD ONLY This command provides data for the 3rd and 4th choppers used in
the HPR400 system.
Chopper C temp (raw A/D)
Chopper D temp (raw A/D)
Chopper C current (amps)
Chopper D current (amps)
Data:
None
Return value:
Above info space-delimited.
Sample:
>13397<
>133CCT0482 CDT0021 CCC0000 CDC000050<
134 READ ERROR LOG ALL HPR SYSTEMS This command will return the last 4 error codes the system
encountered. The log will only record errors (error code values
greater than 0). It ignores error code 0, which indicates no error
orthat an error has been cleared.
The error codes are listed space-delimited, most recent error first.
Data:
None
Return value:
Error – most recent (see table IV Error Codes)
Error #2
Error #3
Error – oldest error
Sample:
>13498<
>134020 020 024 0534A<
Command table (13 of 14)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR800XD and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR800XD Specifications

General IconGeneral
BrandHypertherm
ModelHyPerformance Plasma HPR800XD
CategoryCutter
LanguageEnglish

Related product manuals