EasyManua.ls Logo

Hypertherm Powermax65 SYNC - Page 4

Hypertherm Powermax65 SYNC
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Serial Communication Programmer Reference Guide
4 810400 Reference Guide Powermax65/85/105 SYNC
Read the plasma power supply settings that are permitted for the installed cartridge .......... 26
0x3001 (permitted operating mode setting)......................................................................... 26
0x3002, 0x3003 (permitted minimum and maximum output current (A) settings)...... 26
0x3004, 0x3005 (permitted minimum and maximum gas pressure settings)............... 26
Example request and response................................................................................................ 27
Write operating settings and put the plasma power supply into remote control mode.......... 28
0x3080 (operating mode setting) ........................................................................................... 28
0x3081 (output current (A) setting)........................................................................................ 28
0x3082 (gas pressure setting) ................................................................................................ 29
Example request and response................................................................................................ 29
Remote control mode indicator on the plasma power supply .......................................... 30
Do a check for an active fault............................................................................................................... 30
0x301A (active fault code)........................................................................................................ 30
Example request and response................................................................................................ 31
Fault code list............................................................................................................................... 32
Start and stop a gas test....................................................................................................................... 36
0x3180 (coil: gas test)............................................................................................................... 36
Example request and response................................................................................................ 37
Do a quick restart or clear fault code 0-50-0 .................................................................................. 38
0x308E, 0x308F (quick restart with approval)..................................................................... 38
Example request and response................................................................................................ 39
Exit remote control mode ...................................................................................................................... 40
Example request and response................................................................................................ 40
Get data from the plasma power supply ....................................................................................................... 41
Read the plasma power supply settings............................................................................................ 41
0x3010 (operating mode).......................................................................................................... 41
0x3011 (output current (A) setting)........................................................................................ 41
0x3012 (gas pressure setting)................................................................................................. 42
Example request and response................................................................................................ 42
Read the actual output of the plasma power supply ...................................................................... 43
0x3018 (actual output current)................................................................................................ 43
0x3019 (actual gas pressure) .................................................................................................. 43
Example request and response................................................................................................ 43
Read the total cut counts for this plasma power supply................................................................ 44
0x3028 (total number of torch starts bytes 1 and 0)...................................................... 44
0x3029 (total number of starts bytes 3 and 2) ................................................................ 45
0x302A (cumulative pilot arc time bytes 1 and 0)........................................................... 45
0x302B (cumulative pilot arc time bytes 3 and 2)........................................................... 45

Table of Contents

Other manuals for Hypertherm Powermax65 SYNC

Related product manuals