Serial Communication Programmer Reference Guide
Powermax65/85/105 SYNC Reference Guide 810400 5
0x302C (total number of arc transfers – bytes 1 and 0)................................................... 45
0x302D (total number of arc transfers – bytes 3 and 2)................................................... 46
0x302E (cumulative arc transfer time – bytes 1 and 0)..................................................... 46
0x302F (cumulative arc transfer time – bytes 3 and 2)..................................................... 46
Example request and response................................................................................................ 47
Read the 16-character UID number for the installed cartridge ................................................... 48
0x3030 – 0x3037 (cartridge UID, bytes 0 – 15)................................................................ 48
Example request and response................................................................................................ 49
Read the total cut counts for the installed cartridge....................................................................... 50
0x3040 (total number of starts)............................................................................................... 50
0x3041 (cumulative pilot arc time).......................................................................................... 50
0x3042 (total number of arc transfers).................................................................................. 50
0x3043 (cumulative arc transfer time) ................................................................................... 51
Example request and response................................................................................................ 51
Read the 4 most recent faults for the installed cartridge............................................................... 52
0x3044 (fault log 0).................................................................................................................... 52
0x3045 (fault log 1).................................................................................................................... 53
0x3046 (fault log 2).................................................................................................................... 53
0x3047 (fault log 3) .................................................................................................................... 53
Example request and response................................................................................................ 54
Read the name of the installed cartridge........................................................................................... 55
0x3048 – 0x304D (cartridge name, bytes 0 – 11) ............................................................ 55
Example request and response................................................................................................ 56
Read the Start and Motion signal status of the plasma power supply....................................... 57
0x3100 (coil: Start switch signal status) ............................................................................... 57
0x3101 (coil: Motion switch signal status)............................................................................ 57
Example request and response................................................................................................ 58
Flowchart Examples ................................................................................................................ 61