179
Each LLDP frame contains information about how long the LLDP information is valid (age-out
time). If no new LLDP frame is received within the age out time the LLDP information is
removed and the Age-Out counter is incremented.
Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3
seconds.
Clear: Clears the counters for the selected port.
Refresh: Click to refresh the page.
LLDP PoE Statistics
This page displays the current status for all PoE ports.
To display PoE Statistics in the web interface:
Click Monitor / PoE
Check the Auto-Refresh check box to have the page automatically refresh every 3 seconds.
LLDP PoE Statistics Parameters:
This is the logical port number for this row.
Each PD is classified according to a class that defines the maximum power the PD will use. The
PD Class shows the PDs class. Five classes are defined:
Class 0: Max. Power 15.4 W
Class 1: Max. Power 4.0 W
Class 2: Max. Power 7.0 W
Class 3: Max. Power 15.4W
Class 4: Max. Power 30.0 W
The Power Requested shows the requested amount of power the PD needs to reserve.
The Power Allocated shows the amount of power the switch has allocated for the PD.
The Power Used shows how much power the PD is currently using.
Current Used shows how much current the PD is currently using.
Priority shows the port's priority configured by the user.