Table 4. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1011 1922 Power supply 2 non-power fault 1. CEC drawer power supply 2
Location: U1.1-V2
2. Primary I/O backplane
Location: U0.1-P1
1011 1923 Power supply 2 domain fault 1. CEC drawer power supply 2
Location: U1.1-V2
2. Primary I/O backplane
Location: U0.1-P1
1011 1924 Power supply 2 cooling fault 1. CEC drawer power supply 2
Location: U1.1-V2
2. CEC drawer fan controller card
Location: U1.1-X2
3. Primary I/O backplane
Location: U0.1-P1
1011 1926 Power supply 2 missing CEC drawer power supply 2
Location: U1.1-V2
1011 1B01 12V loading 1. Replace power supply 1
Location: U0.1-V1
2. If power supply 2 is present
(no cooling unit), use removed
power supply 1 to replace
power supply 2
3. Primary I/O backplane
Location: U0.1-P1
1011 1B02 5V loading 1. Replace power supply 1
Location: U0.1-V1
2. If power supply 2 is present
(no cooling unit), use removed
power supply 1 to replace
power supply 2
3. Primary I/O backplane
Location: U0.1-P1
1011 1B03 3.3V loading 1. Replace power supply 1
Location: U0.1-V1
2. If power supply 2 is present
(no cooling unit), use removed
power supply 1 to replace
power supply 2
3. Primary I/O backplane
Location: U0.1-P1
1011 1B04 -12V loading 1. Replace power supply 1
Location: U0.1-V1
2. If power supply 2 is present
(no cooling unit), use removed
power supply 1 to replace
power supply 2
3. Primary I/O backplane
Location: U0.1-P1
172 Service Guide