Table 5. Firmware Error Codes. (continued)
Error Code Description Action/
Possible Failing FRU
2803 0001 RTC not updating - RTC initialization
required
Errors reported against the real-time
clock can be caused by low battery
voltage and (more rarely) power
outages that occur during normal
system usage. These errors are
warnings that the real-time clock data
content needs to be re-established
and do not require any FRU
replacement unless the error is
persistent. When one of these errors
occurs, the time and date information
has been lost.
To set/restore the time and date, use
the operating system facility.
If the error is persistent:
1. Replace the battery.
2. Replace primary I/O backplane
Location: U0.1-P1
2803 0002 Bad time/date values 1. Set time and date.
2. Refer to Action under error code
28030001.
2803 0003 RTC not updating - not correctable Replace primary I/O backplane
Location: U0.1-P1
2803 0004 RTC operating mode parameters (eg.
data mode) changed
1. Set time and date.
2. Refer to Action under error code
28030001.
2803 0005 RTC battery error 1. Replace the battery.
Note: Password, time, and date
need to be set.
2. Refer to Action under error code
28030001.
2900 0002 Keyboard/mouse controller failed
self-test
Replace primary I/O backplane
Location: U0.1-P1
29A0 0003 Keyboard not present/detected 1. Keyboard
2. Keyboard cable
3. Replace primary I/O backplane
Location: U0.1-P1
29A0 0004 Keyboard stuck key detected 1. Keyboard
2. Replace primary I/O backplane
Location: U0.1-P1
29B0 0004 Mouse not present/detected 1. Mouse
2. Replace primary I/O backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index
211

Table of Contents