Table 6. Service Processor Error Codes. (continued)
Error Code Description Action/
Possible Failing FRU
4B2F 24A4 Processor system and error code
generation/logging detected 6W
processor fault
Processor card
Location: U1.1-P1-C1
4B2F 25BB Processor system and error code
generation/logging detected 1W
processor card fault
1W Processor card
Location: U1.1-P1-C1
4B2F 25BD Processor system and error code
generation/logging detected 2W
processor card fault
2W Processor card
Location: U1.1-P1-C1
4B2F 25BE Processor system and error code
generation/logging detected 4W
processor card fault
4W Processor card
Location: U1.1-P1-C1
4B2F 25BF Processor system and error code
generation/logging detected 6W
processor card fault
6W Processor card
Location: U1.1-P1-C1
4B2F 25CB 1W processor card fault Replace the processor card
Location: U1.1-P1-C1
4B2F 25EA 4W processor card fault Replace the processor card
Location: U1.1-P1-C1
4B2F 25EB 2W processor card fault Replace the processor card
Location: U1.1-P1-C1
4B2F 25F2 6W processor card fault Replace the processor card
Location: U1.1-P1-C1
4B2F 263D Processor system and error code
generation/logging detected dummy
riser card fault
Dummy riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
4B2F 2687 Processor system and error code
generation/logging detected RIO
adapter fault
RIO adapter
Location: U0.1-P1.1
4B2F 271A Processor system and error code
generation/logging detected primary
I/O backplane fault
Primary I/O backplane
Location: U0.1-P1
4B2F 271D Processor system and error code
generation/logging detected
secondary I/O backplane fault
Secondary I/O backplane
Location: U0.2-P1
4B2F 283A Processor system and error code
generation/logging detected CEC
backplane fault
1. Processor card
Location: U1.1-P1-C1
2. CEC backplane
Location: U1.1-P1
4B2F 285D Processor system and error code
generation/logging detected fan
controller card fault
Fan controller card
Locations:
U0.1-X2
U1.1-X2
352 Service Guide