Table 6. Service Processor Error Codes. (continued)
Error Code Description Action/
Possible Failing FRU
4B2F 288D Processor system and error code
generation/logging detected memory
riser fault
1. Go to service processor memory
configuration/deconfiguration
menu to verify memory DIMMs
state. See ″Memory
Configuration/Deconfiguration
Menu″ on page 384 for more
information.
2. Memory riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
4B2F 2A00 Processor system and error code
generation/logging detected 6W
processor fault
Processor card
Location: U1.1-P1-C1
4B2F 300A Processor system and error code
generation/logging detected 32MB
DIMM fault
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
4B2F 300B Processor system and error code
generation/logging detected 128MB
DIMM fault
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
4B2F 300C Processor system and error code
generation/logging detected 256MB
DIMM fault
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
4B2F 300D Processor system and error code
generation/logging detected 512MB
(stacked) DIMM fault
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
4B2F 300E Processor system and error code
generation/logging detected 512MB
(unstacked) DIMM fault
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
4B2F 301F Processor system and error code
generation/logging detected 128MB
DIMM fault
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Chapter 5. Error Code to FRU Index
353