2. After 45 seconds, reconnect the server to the power source and turn on the server.
3. Retry the operation.
4000008b-00000000 One or more of the Storage Management IP addresses has changed.
Explanation: This message is for the use case where an IP address for the Storage Management has changed
May also be shown as 4000008b00000000 or 0x4000008b00000000
Severity: Info
Alert Category: System - IMM Network event
Serviceable: No
CIM Information: Prefix: IMM and ID: 0139
SNMP Trap ID: 37
Automatically notify Support: No
User response: Information only; no action is required.
80010002-0701xxxx Numeric sensor [NumericSensorElementName] going low (lower non-critical) has asserted.
(CMOS Battery)
Explanation: This message is for the use case when an implementation has detected a Lower Non-critical sensor
going low has asserted.
May also be shown as 800100020701xxxx or 0x800100020701xxxx
Severity: Warning
Alert Category: Warning - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0476
SNMP Trap ID: 13
Automatically notify Support: No
User response: Replace the system battery.
80010202-0701xxxx Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation: This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102020701xxxx or 0x800102020701xxxx
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 1
Automatically notify Support: Yes
User response: If the specified sensor is CMOS battery, replace the system battery. If the specified sensor is Planar
3.3V or Planar 5V, (trained technician only) replace the system board. If the specified sensor is Planar 12V, complete
the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
3. Follow actions in "Power Problems and Solving Power Problems".
4000008b-00000000 80010202-0701xxxx
Appendix A. Integrated management module II (IMM2) error messages 383