S.3050007 [S.3050007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity: Error
User response: Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2. Reflash UEFI image.
3. (Trained service technician only) Replace the system board.
S.3058004 [S.3058004] A Three Strike boot failure has occurred. The system has booted with default UEFI
settings.
Explanation: POST failure has occurred! System booted with default settings.
Severity: Error
User response: Complete the following steps:
1. This event resets UEFI to the default settings for the next boot. If successful, user is forced into F1 setup. Original
UEFI settings are still present.
2. If User did not intentionally trigger the reboots, check logs for probable cause.
3. Undo recent system changes (settings or devices added). If not recent system changes, remove all options then
remove CMOS battery for 30 seconds to clear CMOS contents. Verify that the system boots. Then, re-install
options one at a time to locate the problem.
4. Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
5. Reflash UEFI firmware.
6. Remove and re-install CMOS battery for 30 seconds to clear CMOS contents
7. (Trained service technician only) Replace the system board.
S.3060007 [S.3060007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity: Error
User response: Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2. Reflash UEFI image.
3. (Trained service technician only) Replace the system board.
S.3070007 [S.3070007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity: Error
User response: Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2. Reflash UEFI image.
3. (Trained service technician only) Replace the system board.
S.3050007 S.3070007
674
IBM System x3550 M4 Type 7914: Installation and Service Guide

Table of Contents

Other manuals for IBM System x3550 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M4 and is the answer not in the manual?

IBM System x3550 M4 Specifications

General IconGeneral
ProcessorIntel Xeon E5-2600 series
ChipsetIntel C600 series
MemoryUp to 768 GB
StorageUp to 8 x 2.5" hot-swap drives
Form Factor1U rack
Power Supply750 W AC
Network Interface4 x 1 GbE
RAID SupportRAID 0, 1, 10
Expansion Slots3 x PCIe 3.0 slots
Operating System SupportWindows Server, RHEL, SUSE, VMware
ManagementIntegrated Management Module II (IMM2)

Related product manuals