EasyManuals Logo

iDect FC6A series User Manual

iDect FC6A series
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #297 background imageLoading...
Page #297 background image
FC6A S
ERIES
M
ICRO
S
MART
A
LL
-
IN
-O
NE
T
YPE
U
SER
’
S
M
ANUAL
FC9Y-B1722 7-11
7: HMI F
UNCTION
Clearing TP (Timer Preset Values) and CP (Counter Preset Values)
1. In step 5 of "Reflecting TP (Timer Preset Values) and CP (Counter Preset Values) in the User Program" on page 7-10, select
Clear with the (up) and (down) buttons, and press the (OK) button.
The changes made to the timer and counter preset values are deleted. The preset values of the user program in the ROM remain
as they are before those values are modified. The device values return to the values before they are modified.
Note: The preset values can also be reflected to the user program in ROM using WindLDR. Select Online > Monitor > Start Monitor. Select
Online > PLC > Status to display the PLC Status dialog box, and click the Confirm button under Timer/counter preset value modification
state. Once preset values are confirmed, they cannot be restored to their previous values, even if they are cleared.
T/C Change Status:
T/C is changed
Clear
Confirm

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the iDect FC6A series and is the answer not in the manual?

iDect FC6A series Specifications

General IconGeneral
BrandiDect
ModelFC6A series
CategoryController
LanguageEnglish