iDirect Evolution 8000 Series Satellite Router Installation and Safety Manual 13
iCONNEX e800 Satellite Router Specifications
3.2.2 Power Specifications
Ensure that the installation site can accommodate the power specifications for the iCONNEX
e800 Satellite Router as defined in Table 6.
Operational Vibration
(10 minutes per axis)
The iCONNEX e800 remains operational when exposed to 0.21 grms
with the following profile:
Operational Shock The iCONNEX e800 shall remain operational when exposed to 10g,
10ms half sine on x, y, z axis.
Conformal Coating HUM/SEAL 1B73
Table 6. e800 iCONNEX Satellite Router Power Specifications
Category Description
Input Voltage Range +24 VDC or +48 VDC
DC Power F-Connector TX Out, +24 VDC, 3.5A maximum power supply to BUC or,
TX Out, +48 VDC, 3A maximum power supply to BUC
Protection Internal, primary current fuse, inside power supply
Over current protection
Short protection
Power Factor Correction Complies with EN61000-3-2 and EN61000-3-3
Efficiency 86% typical
Input Transient Response 0.5 msec for 50% load change typical
Table 5. e800 iCONNEX Satellite Router Mechanical and Environmental
Specifications (continued)
Category Description
Frequency Slope PSD
5 to 350 Hz 0 0.0001 g2/Hz
350 to 500 Hz -6 dB/octave
500 Hz 0 0.00005 g2/Hz