40 iDirect Evolution 8000 Series Satellite Router Installation and Safety Manual
Maintaining the Remote
4.8.1 Temperature Control
The e8350 Satellite Router has a built-in temperature sensor that measures the circuit board
temperature. If the temperature exceeds a defined threshold, the e8350 Satellite Router
alerts the NMS to the high temperature condition. See Chapter 3, Evolution 8000 Series
Specifications, for the proper temperature range.
Various conditions can cause the e8350 Satellite Router to have an elevated internal
temperature, such as:
Objects blocking the enclosure vents
Dust accumulated on the enclosure or the vents
Ambient temperature elevated beyond the specified limits
4.8.2 Dust Removal
A dusty environment requires frequent maintenance. With the powered removed, use a
slightly damp cloth with the excess moisture wrung out (not a saturated, dripping-wet cloth)
to wipe away the dust that collects on the outside of the enclosure.
Vacuum the dust off the enclosure vents. Vacuum the circuit board through the enclosure
vents, if possible.