Specifications
2011-03-09 43
7.2.2 Fiber
A point-to-point connection is necessary. Operation with multiple patch
panels is allowed. Routing over active network components, such as
Ethernet Hubs, Switches or Routers, is not allowed.
Type of Interconnect Cable
(Cable notations according to VDE)
Type of cable Specifications
Single-mode 9μm Two fibers 9μm
I-V(ZN)H 2E9 (in-house patch cable)
I-V(ZN)HH 2E9 (in-house breakout cable)
I/AD(ZN)H 4E9 (in-house or outdoor
breakout cable, resistant)
A/DQ(ZN)B2Y 4G9 (outdoor cable, with
protection against rodents)
Multi-mode 50μm Two fibers 50μm
I-V(ZN)H 2G50 (in-house patch cable)
I/AD(ZN)H 4G50 (in-house or outdoor
breakout cable, resistant)
Multi-mode 62.5μm Two fibers 62.5μm
I-V(ZN)HH 2G62,5 (in-house breakout
cable)
A/DQ(ZN)B2Y 4G62,5 (outdoor cable,
with protection against rodents)
Maximum Acceptable Cable Length
Type of cable Maximum Acceptable Cable Length
Single-mode 9μm 10,000 m (32,800 ft)
Multi-mode 50μm (OM3) 1,000 m (3,280 ft)
Multi-mode 50μm 400 m (1,300 ft)
Multi-mode 62.5μm 200 m (650 ft)
If you use single-mode SFPs with multi-mode fibers, you normally can
double the maximum acceptable cable length.
Pos: 50 /806-IHSE/ Technische Daten/Verbi ndungskabel/Verbindu ngskabel (LWL) _Steckverbinder 477- xx @ 5\mod_1278954447542_6. doc @ 43740 @
Type of Connector
Connector
LC Connector