p2 Section 4. Times. Version 1.01 CONCEPT IQ. Installation & Programming Manual.
TIMEZONES
TimeZones can be programmed to define a Start time and End time, and the Days of the Week on which the
TimeZone will be valid. TimeZone programming also provides a “Holiday” option to be enabled when assign-
ing the Days, to allow the TimeZone to still be valid on any dates defined as Holidays.
Once programmed, TimeZones can be used to arm & disarm Areas &/or control Auxiliary outputs automati-
cally.
START AND END TIMES
The Start and End Times are defined in 4 separate Addresses for each TimeZone.
TIMEZONE 1 START HOUR Default = 9
This Address defines the Hour component of the Start Time.
TIMEZONE 1 START MINUTE Default = 0
This Address defines the Minute component of the Start Time.
TIMEZONE 1 END HOUR Default = 17
This Address defines the Hour component of the End Time.
TIMEZONE 1 END MINUTE Default = 0
This Address defines the Minute component of the End Time.
TIMEZONE 1 DAYS OF THE WEEK Default = 2, 3, 4, 5, 6 Selected. (Mon - Fri)
Option : When Selected:
1 Sunday ¯|
2 Monday |
3 Tuesday | The TimeZone will be valid on the specified Day, or Days,
4 Wednesday | unless the date has been defined as a Holiday.
5 Thursday |
6 Friday |
7 Saturday _|
8 Holiday The TimeZone will always be valid on the Days of the Week selected above,
regardless of whether the date has been defined as a Holiday.
The default setting is 9:00 – 17:00 on all Weekdays (Working Hours)
TIMEZONE 2 (5 Addresses)
The default setting is 9:00 – 13:00 on Weekend Days (Overtime Hours)
TIMEZONE 3 (5 Addresses)
The default setting is 7:00 – 20:00 on every Day (Day-time)
TIMEZONE 4 (5 Addresses)
The default setting is 20:00 – 7:00 on every Day (Night-time)
Address
Data type:
Value
790
Range:
0 - 23
791
Range:
0 - 59
792
Range:
0 - 23
793
Range:
0 - 59
794
Data type:
Option
795
to
799
800
to
804
805
to
809

Table of Contents

Other manuals for Inner Range CONCEPT IQ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inner Range CONCEPT IQ and is the answer not in the manual?

Inner Range CONCEPT IQ Specifications

General IconGeneral
BrandInner Range
ModelCONCEPT IQ
CategorySecurity System
LanguageEnglish

Related product manuals