Section 3. General opts. Version 1.01 p1CONCEPT IQ. Installation & Programming Manual.
General
Section 3. General System options
General Options
General Options.............................................................................................................................1
Emergenency Options ...................................................................................................................2
Address
868
869
868
Data type:
Option
GENERAL OPTIONS Default = Options 4 & 8 Selected
Option: When Selected:
1 Enables auto-isolate on arming. (Applies to “Delayed” Zone Type only)
2 Enables Quick arming. (Area number key, then <ON> or <HOME> -No PIN code required)
3 PIN codes are 6 digits. (PIN codes are normally 4 digits)
4 * Enable Real-time clock to be synchronized to the AC Mains frequency. (50Hz).
5 Enables automatic battery testing.
6 Configures all “Key switch” Zone Types (Types 8 & 9) for “Latching” (Double-pole) operation.
(Key-switch Zones are normally “Momentary” operation)
7 Enables Master User/s to edit Telephone numbers (Via <NEXT>, 27)
8 * Enables display of Zone activity on Terminals when Area/system is disarmed.
* Selected in Defaults.
NOTES:
Auto-Isolate on arming.
Any “Delayed” Zone Inputs (Zone Type 1) in the Area/s being armed, that are in the Alarm state when the
Exit Delay timer is about to expire, will automatically be isolated.
Note that any other types of Zones that need to be Isolated when arming the system must be manually
Isolated before the arming procedure is commenced. (Via <NEXT> 1, 0.)
If enabled, Auto-Isolate will operate regardless of how the system is armed. (e.g. Via User, Key-switch,
One-touch arming, Remote, etc.)
Quick Arming.
Single Area System: Quick Arming procedure is always <1>, <ON> or <1>, <HOME>.
Multi-Area System: Quick Arming procedure is <Area Number>, <ON> or <Area Number>, <HOME>.
If the Terminal is programmed for Single Area Mode, only the associated Area can be Armed.
6 Digit PIN Codes.
If this option is selected:
- The Factory default Installer PIN Code (User 1) becomes 2 3 4 5 6 7
- The Factory default Master PIN Code (User 2) becomes 0 1 2 3 4 5
- All PIN Codes must be 6 digits long.
Automatic battery test.
IMPORTANT NOTE: Enabling Automatic battery test is highly recommended as a Low Battery Alarm can
only be generated if the battery falls below 11.2V during a Battery Test, or when the AC input is not present.
When this function is enabled the system will test the battery every 8 hours; At Midnight, 8 AM and 4 PM
every day.
This involves disconnecting the AC supply for 4 minutes and measuring the battery voltage under load.
If the battery voltage falls below 11.2V +/-0.3V, a “Low Battery” System Input alarm will be generated.
Key-switch operation.
Momentary: (Default setting) When this function is enabled, the state of the Area will toggle whenever
there is a “Seal to Alarm” transition on the Keyswitch Zone. The “Alarm to Seal” transition will be ignored.
Latching: When this function is enabled, the Keyswitch will Arm the Area when it goes “Unsealed” and
Disarm the Area when it returns to “Sealed”.