CONCEPT IQ. Installation & Programming Manual.
Install
p3
Control Module. 995501
Control Module Parts List
- Control Module PCB mounted in metal enclosure.
- User Manual.
- Installation Manual. (This document)
- Installation Kit containing:
- 4 x Pan Head Self-tapping screws 4x6mm. Used to secure the enclosure cover.
- 5 x plastic “D” bungs. Must be fitted to all unused cable entry cutouts in the cover.
- Telecom Line cord. (Note: Non-standard configuration. Only suitable for use with this product)
- 10 x 3k3 End-of-line resistors. (orange-orange-black-brown-brown) Used for Single EOL / Dual EOL / Zone Doubling.
- 10 x 6k8 End-of-line resistors. (blue-grey-black-brown-brown) Used for Dual EOL or Zone Doubling.
- 10 x 1k End-of-line resistors. (brown-black-black-brown-brown) Used for Zone Doubling.
- Tamper switch.
- Tamper switch bracket.
- 2 x 6 Way plug-on screw terminals. (Only for PCBs that do not have fixed terminal blocks fitted)
- 1 x 3 Way plug-on screw terminals. (Only for PCBs that do not have fixed terminal blocks fitted)
- 5 x 2 Way plug-on screw terminals. (Only for PCBs that do not have fixed terminal blocks fitted)
- 2 x 6.3mm Tamper switch connectors.
- Battery connection lead, 220mm, pre-assembled.
- 1 x 1 Amp M205 (20mm) Fuse. (Spare)
Electrical Specifications
Power Supply I/P: Plug pack Mains Supply: 240V AC -10% / +10%. 50 Hertz.
Plug pack Output: 16V AC. 1.0 Amperes.
PCB AC Input Voltage: 16V AC.
Battery Capacity: 12V. 7AH. Sealed Lead Acid Battery.
DC Operating Voltage (Batt I/P) 9.5 to 14 V DC. (Low Battery alarm activated at 11.2V +/- 0.3V)
Battery Input Fuse: 1 Ampere.
Power Supply O/P: Current: Total combined current required by devices connected to
“DET+” and “LAN+” must not exceed 600 milliAmps.
Fuse Protection: 1 Ampere. (DET+ and LAN+)
Auxiliary Outputs: OUT1 (Strobe) / OUT2 Max. switched current = 200mA per Auxiliary. (Open Collector)
Siren Output (SPK): Maximum Load: 8 Ohms. (i.e. 1 x 8 Ohm Speaker only. Additional speakers must
not be connected in parallel)
NOTES: 1) ALWAYS REPLACE FUSES WITH THE SAME FUSE TYPE AND VALUE!
2) See data supplied with detectors and output devices for current consumption.
Mechanical Specifications
Dimensions: Height: 260 mm. Width: 265 mm. Depth: 80 mm.
Weight: 4.2 kg. (Cabinet & cover, PCB and 7AH battery) Plug pack = 0.6kg
Environmental Specifications
Continuous Operating Temperature 0 to +50 °C
Storage Temperature -20 to +70 °C
Relative Humidity (Non condensing) 15 to 85 %
© 2001. Inner Range Pty. Ltd. Part No: 635501
Contents
Control Module Parts List ..............................................................................................................1
Specifications.................................................................................................................................1
Installation Procedure....................................................................................................................2
Connection Details. Zone Inputs (Detectors), Tamper switch and Fuses ................................3
Mode 3 Telephone line connection ..............................................................................................3
Connection Details. Power, Warning devices & LAN .................................................................4
Control Module. Version 1.02

Table of Contents

Other manuals for Inner Range CONCEPT IQ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inner Range CONCEPT IQ and is the answer not in the manual?

Inner Range CONCEPT IQ Specifications

General IconGeneral
BrandInner Range
ModelCONCEPT IQ
CategorySecurity System
LanguageEnglish

Related product manuals