p10 Section 2. Intro. Version 1.01 CONCEPT IQ. Installation & Programming Manual.
To Select the Data to be Viewed or Edited.
When in programming mode, the Memory Address to be viewed or edited can be selected by the following key
sequence:
Press , then the Address ... (2 or 3 digits - 16 to 988), then
Pressing will take you to the next Address.
(This does not apply to Data programmed in sequential Addresses such as PIN codes, Telephone Numbers and
Client codes)
The programming details of each Data Address in the following sections of this manual will only show the actual
Address number (nn...). Remember that the Installer must first access Programming Mode; and the Data Address
Number must be preceded by the <OFF / #> key.
To Edit the Data.
The Data Value at this Address will then be displayed on the Terminal, and can be changed by the following key
sequence:
Press , then the new Data Value or Option setting ... (1 to 16 digits*), then
* Depending on the type of Data required.
To set the Data in the current Address to the Factory Default setting:
Press , then , then
If you make a mistake while entering a value, press and enter that value again followed by the key.
Exiting the Installer Operations.
Press to exit any of the Installer Operations.
4.2 SELECTING AND PROGRAMMING THE DATA.
4. Programming Techniques
4.1 THE SYSTEM DATABASE.
The system programming is stored in Memory Addresses numbered 16 - 988.
Programming the system involves three steps:
1) Enter Programming Mode.
Then for each item of Data to be programmed;
2) Select the Memory Address to be programmed.
3) Program the new Data Value or Options for that Address.