Section 2. Intro. Version 1.01 p13CONCEPT IQ. Installation & Programming Manual.
Intro
5.3 “OPTION” DATA.
Option data is used to allow the Installer to select between two alternatives (Select/De-select, Enable/Disable,
Assign/Un-assign, etc.) for up to 8 Options or Items that relate to a particular feature.
Option Data is displayed on the Zone 1 to 8 Lamps on the LED Terminal.
When a Zone Lamp is ON, the option is Selected. (Enabled or Assigned)
When a Zone Lamp is OFF, the option is De-selected. (Disabled or Un-assigned)
Editing option data.
Option Data is programmed by first selecting the Address of the Data to be edited in the normal manner.
Any number of specific options are then Selected or De-selected by the following method:
1) Check the current setting of the option on the Zone Lamps.
2) For each option that needs to be changed, Press , then the option number (1 to 8), then .
This procedure toggles the setting of the selected option.
i.e. If the option was De-selected, it will be Selected. If the option was already Selected, it will be De-selected.
To Select ALL available options: Press , then , then .
To De-select ALL available options: Press , then , then .
To set ALL available options to the factory default settings: Press , then , then .
Example.
“Dialer Options” are Option Data and are programmed in Address 49. This data sets which types of events will be
reported via dialer: 1 Enable Alarms reported via dialer.
2 Enable Restores reported via dialer.
3 Enable Open / Close reported via dialer.
4 Enable Programming Change reported via dialer.
5 Enable Sending Open Report only if an alarm has occurred.
To Enable “Alarms”, “Restores” and “Open Report only after alarm”, the following procedure would be performed:
1) Enter Installer PIN code; ... , then , then the Programming Mode number; ,
2) Select the Address for Dialer Options. Press , then , then
3) Enable the three options required. (Assuming none of the options are currently enabled)
Press , then , then
Press , then , then
Press , then , then
(Remember that the same key sequence is used to Disable an option that is already Enabled.
4) Check Zone Lamps 1 to 8 to ensure that the required options have been selected successfully.
Zone Lamps 1, 2 and 5 should be ON. All other Zone Lamps should be OFF.
5) Select the next Address or Start Address to program, or Exit Programming Mode.
E.g. To program the data “1 Pause 9 8 7 6 5 4 3 2” as the Primary Telephone Number.
1) Enter Installer PIN code; ... , then , then the Programming Mode number; ,
2) Press , then the Start Address for the Primary Telephone Number , then
3) Press , then the new Data string , then
4) Select the next Address or Start Address to program, or Exit Programming Mode
(Note: The <Next> key is used to program a “PAUSE”).
Sequential Number data is displayed one digit at a time by a sequence of flashing Lamps in the same manner as
Multi-digit numbers described above.

Table of Contents

Other manuals for Inner Range CONCEPT IQ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inner Range CONCEPT IQ and is the answer not in the manual?

Inner Range CONCEPT IQ Specifications

General IconGeneral
BrandInner Range
ModelCONCEPT IQ
CategorySecurity System
LanguageEnglish

Related product manuals