Section 4. Times. Version 1.01 p1CONCEPT IQ. Installation & Programming Manual.
Times
SIREN TIME Default = 5 Minutes
This Address sets the time the siren will sound when an alarm has occurred on a Zone Input.
Note that an alarm on a Zone Input will only activate the Siren when:
- The Zone Type selected is in the range of Type 0 to Type 5. (Address 736 [Zone 1] to 751 [Zone 16])
- The Zone Options must have Option 1 (Silent), Disabled.
- For Zone Types 4 (24Hr Fire) & 5 (24Hr Panic), Siren activation must also be enabled in the “Emergency
Options”. (Address 869: Option 1-Panic alarm sounds Siren. Option 3-Fire alarm sounds Siren)
- The Zone Input must have at least one Area assigned.
The Siren Time does not apply to System Inputs. Siren operation for System Inputs is determined by the
settings in Address 865 - System Input Siren enable, and Address 867 - System Input Siren Type.
KEYPAD LOCKOUT TIME Default = 60 Seconds
This sets the time the Terminal keypad will be locked out when five incorrect logins (PIN code attempts) in a
row have occurred on a keypad.
For Keypad Lockout to function, the setting must be non-zero.
See Section 7; “System Inputs” if Siren activation (Address 865, Option 4) or Dialer activation (Address 866,
Option 4) are required for Keypad Lockout.
Section 4. Time Programming
Siren Time ..................................................................................................................................................1
Keypad Lockout Time................................................................................................................................1
TimeZones
TimeZone 1 Start Hour ..................................................................................................................2
TimeZone 1 Start Minute ...............................................................................................................2
TimeZone 1 End Hour ...................................................................................................................2
TimeZone 1 End Minute ................................................................................................................2
TimeZone 1 Days Of Week ...........................................................................................................2
TimeZone 2 (5 Addresses)............................................................................................................2
TimeZone 3 (5 Addresses)............................................................................................................2
TimeZone 4 (5 Addresses)............................................................................................................2
AC Report Delay........................................................................................................................................3
Holidays
Holiday Month (10 Addresses) ....................................................................................................3
Holiday Day (10 Addresses) ........................................................................................................3
Daylight Saving
Daylight Saving Start Month ........................................................................................................3
Daylight Saving Start Week .........................................................................................................3
Daylight Saving Day-of-week in Start Week ...............................................................................3
Daylight Saving End Month..........................................................................................................4
Daylight Saving End Week ..........................................................................................................4
Daylight Saving Day-of-week in End Week ................................................................................4
Real-Time Clock ........................................................................................................................................4
Other Timers:
“Area Entry Delay” & “Area Exit Delay” Times. See Section 5. Areas.
“Autoarm Prewarn” & Re-Autoarm” Times. See Section 5. Areas.
“Pulse Time” for Pulse Counting feature. See Section 6. Zones
“Auxiliary Timers”. See Section 8. Auxiliaries.
“Door Open Time”. See Section 9. Terminals.
Address
788
789
790
791
792
793
794
795 to 799
800 to 804
805 to 809
810
966 to 984
967 to 985
986
987
988
989
990
991
NEXT 23
788
Data type:
Value
Range:
0 - 255 Min.
789
Data type:
Value
Range:
0 - 255 Sec.