p8 Section 2. Intro. Version 1.01 CONCEPT IQ. Installation & Programming Manual.
3.5 FACTORY DEFAULT DATABASE SETTINGS.
ADDRESS FUNCTION SETTING
16 and 32 Primary & Secondary Telephone Nos No numbers programmed
48 Reporting Format 0. None
49 Dialer options No options selected
50 Maximum attempts 10
51 to 53 Test Report Times No settings
54 Remote connect options 0. No Remote Connect
64 Callback Telephone Number No number programmed
80 Rings to Answer 16
81 Answering machine bypass 0. Disabled
82 Port 0 Comms Tasks 0. None
83 Port 0 Baud Rate 3. 9600
736 Zone Type. Zone 1 1. Delayed. (If Default Options 1 to 16 are selected)
737 Zone Type. Zone 2 2. Handover. (If Default Options 2 to 16 are selected)
738 to 751 Zone Type. Zone 3 to 16 as selected. 0. Instant. (If Default Options 3 to 16 are selected)
752 to 767 Zone Options No options selected.
768 to 783 Zone Area The number of Zones selected in the Default option are assigned to Area 1.
784 & 785 Max Pulse count & Pulse Time 0.
786 End-of-Line Resistor Type 3. Single End-of-line. 3k3
787 Self Test Period 0.
788 Siren Time 5 Minutes
789 Keypad Lockout Time 60 Seconds.
790 to 794 TimeZone 1 9:00 to 17:00. Monday to Friday
795 to 799 TimeZone 2 9:00 to 13:00. Saturday and Sunday
800 to 804 TimeZone 3 7:00 to 20:00. All days including Holidays. (Daytime)
805 to 809 TimeZone 4 20:00 to 7:00. All days including Holidays. (Night-time)
810 AC Report Delay Time 0
816 Auxiliary 1 Event Type 1. Burglary Alarm
817 to 825 Auxiliary 2 to 10 Event Type 0. None
832 to 841 Auxiliary 1 to 10 Time 0
848 Auxiliary 1 Response 2 & 3 Selected. On/Off when Event goes Valid/Invalid (Strobe Output)
849 to 857 Auxiliary 2 to10 Response 2 & 3 Selected. On/Off when Event goes Valid/Invalid
864 Spare
865 to 867 System Input Programming No settings programmed
868 General Options Options 4 & 8 selected. AC Mains sync & Zone activity display on Terminals
869 Emergency Options No options selected
870 & 871 Auto-Arm Timers 0.
872 Door Unlock Time 5 Seconds.
896 to 908 Area Client Codes No codes programmed
928 to 931 Area 1 to 4 Entry Delay Time Area 1: 30 Seconds. Area 2 to 4: 0 Seconds
936 to 939 Area 1 to 4 Exit Delay Time Area 1: 60 Seconds. Area 2 to 4: 0 Seconds
944 to 947 Area Arming Options No options selected
952 to 955 Terminal Associated Area No settings programmed
960 Multi Area Options No options programmed
961 Terminal Area Mode No options programmed
962 Spare
966 to 985 Holidays No Holiday dates programmed
986 & 989 Daylight Saving Start Month & End Month 0. Automatic Daylight Saving adjustment Disabled
987 & 990 Daylight Saving Start Week & End Week 5. Last Week of the Month
988 & 991 Daylight Saving Start Day & End Day 1. Sunday