9BChapter 10: Camera setup
TruVision DVR 44HD User Manual 75
Note: It is not recommended to use the V-stream feature when a analog monitor is used as a
main monitor because the analog main monitor and the V-stream use the same output.
To enable V-streaming:
1. Click the Display Settings > V-stream Encoding.
2. Check Enable V-stream Encoding.
3. Select the desired settings for frame rate and maximum bit rate (Kbps).
4. Click Apply to save the settings and Exit to return to live view.
To configure V-streaming:
The V-stream shows video on the recorder’s BNC output.
1. Click the Display Settings > Display > Video Output Interface and select Main BNC.
2. Under Default View, select the desired view format.
3. Under Sequence Dwell Time, select the desired camera sequence mode.
Note: Sequencing can only be done in single-view display mode.
4. Click the Display Settings > Layout > Video Output Interface and select Main BNC.
5. Select the desired sequence order of the cameras.
6. Click Apply to save the settings and Exit to return to live view.