220 Intermec EasyCoder PF2i, PF4i, and PF4i Compact Industrial—Service Manual
Chapter 15—Troubleshooting
Input buffer on host overfl ow.
- The input buffer should normally be handled by the software of the
host. Increase the receive buffer in the printer to a large value, restart
the host to empty its input buffer and try again.
No response from printer a custom-made program is run (Fingerprint
only).
- The verbosity can be controlled using the Fingerprint instructions
VERBON/VERBOFF and SYSVAR(18). In the Intermec Direct Pro-
tocol, verbosity is disabled by default. Check the program for instruc-
tions that affect the verbosity.
- Verify that the correct communication port is selected as standard
IN/OUT channel.

Table of Contents

Other manuals for Intermec EasyCoder PF4i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PF4i and is the answer not in the manual?

Intermec EasyCoder PF4i Specifications

General IconGeneral
Print technologyDirect thermal
Maximum resolution203 x 203 DPI
Standard interfacesRS-232, USB 2.0
Internal memory16 MB
Power consumption (standby)15 W
Power consumption (printing)300 W
Media thickness3/7.5 mm
Maximum label width104 mm
Maximum label length0.4 m
Maximum roll diameter152.4 /213 mm
Maximum internal memory1 GB
Supported network protocolsTCP/IP, LPR/LPD, FTP, BOOTP, DHCP, HTTP, SNMPv3, SMTP, SNMP-MIB II
Product colorBlue, Silver
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)40 - 104 °F
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth405 mm
Width244 mm
Height178 mm
Weight8000 g