Intermec EasyCoder PF2i, PF4i, and PF4i Compact Industrial—Service Manual 227
Chapter 15—Troubleshooting
Ribbon Sensor
Description:
The ribbon sensor is not working properly.
Possible Causes and Suggested Remedies:
Bad sensor adjustment (Fingerprint only).
- Adjust the sensor in the Setup Mode as described in Chapter 6.4.
Bad connection or faulty sensor.
- Cable between the ribbon sensor and J56 on the CPU board dam-
aged or not correctly connected?
- Sensor blocked by dust or foreign matters? Clean.
- Faulty ribbon sensor? Replace.
Bad detection pattern inside ribbon supply bobbin.
- Check the black and silvery sector pattern at the inner end of the
ribbon supply bobbin for scratches or dust.

Table of Contents

Other manuals for Intermec EasyCoder PF4i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PF4i and is the answer not in the manual?

Intermec EasyCoder PF4i Specifications

General IconGeneral
Print technologyDirect thermal
Maximum resolution203 x 203 DPI
Standard interfacesRS-232, USB 2.0
Internal memory16 MB
Power consumption (standby)15 W
Power consumption (printing)300 W
Media thickness3/7.5 mm
Maximum label width104 mm
Maximum label length0.4 m
Maximum roll diameter152.4 /213 mm
Maximum internal memory1 GB
Supported network protocolsTCP/IP, LPR/LPD, FTP, BOOTP, DHCP, HTTP, SNMPv3, SMTP, SNMP-MIB II
Product colorBlue, Silver
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)40 - 104 °F
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth405 mm
Width244 mm
Height178 mm
Weight8000 g