Intermec EasyCoder PF2i, PF4i, and PF4i Compact Industrial—Service Manual 225
Chapter 15—Troubleshooting
15.11 Sensor Malfunctions
Label Stop Sensor (LSS)
Description:
Label (ticket) gap or black mark not detected by the label stop sensor (LSS)
or wrong amount of media feed.
Possible Causes and Suggested Remedies:
Lost or obsolete media feed data, for example after a headlift, change
of media, or replacement of the sensor.
- In Fingerprint, perform a TESTFEED operation, for example by
simultaneously pressing <Shift> and <Feed> or selecting the Testfeed
option in the Setup Mode.
- In IPL, adjust the media feed by pressing the Feed/Pause button.
Bad LSS lateral alignment.
- Check that the gaps or marks actually pass between the upper and
lower parts the label stop sensor (lateral alignment), see Chapter 7.5.
- Check that both parts of the LSS are adjusted to the same lateral
position, see Chapter 7.5.
• Light path obstructed.
- Check that both the upper and lower sensors as well as the windows
in the upper and lower guide plates are clean and free from dust,
stuck labels, or other matters that may interfere with the path of light.
Printer set for wrong media type.
- Set up the printer for the correct media type.
Media feed detection using PRSTAT (Fingerprint only).
- PRSTAT AND 8 only checks for out-of-media conditions once as
opposed to the normal error checking (errors 1005 and 1031) that
checks for out-of-media conditions more or less continuously. Thus.
when using PRSTAT, a dark spot or a bad media angle can give an
incorrect out-of-media indication, especially when using tickets (w.
mark).
• Bad connection
- Check the LSS cables and make sure that they are correctly connected
to J54 and J55 on the CPU board, see Chapter 13.3.
Faulty sensor or diode.
- Replace LSS as described in Chapter 7.5.
CPU board not confi gured for the right type of printer.
- Reconfi gure the CPU board as described in Chapter 13.8.

Table of Contents

Other manuals for Intermec EasyCoder PF4i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PF4i and is the answer not in the manual?

Intermec EasyCoder PF4i Specifications

General IconGeneral
Print technologyDirect thermal
Maximum resolution203 x 203 DPI
Standard interfacesRS-232, USB 2.0
Internal memory16 MB
Power consumption (standby)15 W
Power consumption (printing)300 W
Media thickness3/7.5 mm
Maximum label width104 mm
Maximum label length0.4 m
Maximum roll diameter152.4 /213 mm
Maximum internal memory1 GB
Supported network protocolsTCP/IP, LPR/LPD, FTP, BOOTP, DHCP, HTTP, SNMPv3, SMTP, SNMP-MIB II
Product colorBlue, Silver
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)40 - 104 °F
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth405 mm
Width244 mm
Height178 mm
Weight8000 g

Related product manuals