224 Intermec EasyCoder PF2i, PF4i, and PF4i Compact Industrial—Service Manual
Chapter 15—Troubleshooting
In case the addresses are not in the same network segment, the printer
may not be reachable from the LAN side. Check the confi guration
with the administrator.
Pinging the Printer
Start the Command Prompt. In the Command Prompt, type Ping
<printer IP-Address> and then click OK.
This command sends an echo command to the EasyLAN to check
if the PC and the printer can reach each other through the network.
The following fi gure shows a correct response to the Ping command.
The rst reply to the fi rst Ping command often takes more time than
the following. This is a normal behavior. The fi rst time the Ping com-
mand is executed, the PC needs some extra time to perform a “dis-
covery” of the network address (ARP request). The Ping command
makes the printer’s network LED fl ash green.
If you have completed the test procedure and all the conditions are
met, but you do not get any answer to the Ping command, then you
probably have a hardware problem.
Description:
The performance of a Wireless network connection ceases to work or the
performance deteriorates after having worked properly for some time after
installation.
Possible Causes and Suggested Remedies:
Bad radio connection between printer and access point.
- Either the printer or the access point has been moved after installa-
tion or some kind of obstruction has come between printer and access
point. In principle, there should be a free line-of sight between the
access point and the antenna. There is also a distance limit.
Check the signal strength.
- Check network test label for statistics.
- Try moving either the printer or the access point (or both) or con-
sider fi tting a higher gain antenna.
Slow response.
- Too many devices associated with the same access point.

Table of Contents

Other manuals for Intermec EasyCoder PF4i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PF4i and is the answer not in the manual?

Intermec EasyCoder PF4i Specifications

General IconGeneral
Print technologyDirect thermal
Maximum resolution203 x 203 DPI
Standard interfacesRS-232, USB 2.0
Internal memory16 MB
Power consumption (standby)15 W
Power consumption (printing)300 W
Media thickness3/7.5 mm
Maximum label width104 mm
Maximum label length0.4 m
Maximum roll diameter152.4 /213 mm
Maximum internal memory1 GB
Supported network protocolsTCP/IP, LPR/LPD, FTP, BOOTP, DHCP, HTTP, SNMPv3, SMTP, SNMP-MIB II
Product colorBlue, Silver
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)40 - 104 °F
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth405 mm
Width244 mm
Height178 mm
Weight8000 g

Related product manuals