EasyManua.ls Logo

Intermec SR61

Intermec SR61
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 — Configuration Command Reference
SR61 Cordless Scanner User’s Manual 47
Good Read Beep Duration
Sets the length of the SR61 good read beeps. You can set Good
Read Beep Duration to a value from 0 (off) to 2550 ms.
Use Good Read Beep Duration in combination with Beep
Volume and Beep Frequency to define beeps according to
operator preference and work environment.
Good Read Beep Number
Establishes the number of beeps used for the good read beep:
one, two, or none.
Good Read Beep Timing
Sets the good read beep to occur either before or after successfully
transmitting data.
Good Read LED Duration
Sets the amount of time the green Status light stays on after a
good read. You can set Good Read LED Duration to a value from
0 (off) to 5110 ms. When the Status light is on due to a long
duration setting, the SR61 can still read new bar codes and
receive commands.
Interleaved 2 of 5
Enables or disables decoding of Interleaved 2 of 5 symbology.
Interleaved 2 of 5 is a high-density, self-checking, continuous
numeric symbology mainly used in inventory distribution and
the automobile industry.
Japan Post
SR61xA (area imager) and SR61xE (near-far range area imager)
only. Enables or disables decoding of Japan Post 4-state code
symbology. Japan Post is a simple and efficient postal bar coding
scheme.
Lighting Goal
SR61xA (area imager) and SR61xE (near-far range area imager)
only. The lighting goal is the average light intensity that the SR61
tries to achieve when capturing an image. Do not change this
setting without assistance from a representative from the
Intermec Engineering Department.