Chapter 4 — Configuration Command Reference
SR61 Cordless Scanner User’s Manual 51
Setup Beep
Enables or disables the setup beep. When you successfully scan
a configuration bar code, you hear the setup beep, and the
configuration of the SR61 is changed.
Stacked Code Crackle
SR61xV (linear imager) and SR61xL (laser scanner) only. Enables
or disables the crackle sound when you scan a stacked (2D) bar
code.
Standard 2 of 5
Enables or disables decoding of Standard 2 of 5 symbology.
Standard 2 of 5 is a low-density numeric symbology that encodes
all information in the bars separated by fixed-width spaces.
Standard 2 of 5 is used in warehouse sorting, photofinishing, and
airline ticketing.
Symbology Identifier
Symbology identifiers allow you to indicate the type of data being
sent by prepending an identifier. You can prepend one of the
following types of character strings to identify which symbology
the data is using.
Symbology Identifier Options
Character
String
Description
AIM identifier The AIM Standard for symbology identifiers
consists of a three-character structure indicating the
symbology and the optional features of the
symbology. For more information about the AIM
Standard for symbology identifiers, refer to the AIM
ISO/IEC Standard.
User-defined
symbology
identifier (UDSI)
The user-defined symbology identifier (UDSI) is
one to four ASCII characters in length. You can
configure user-defined symbology identifiers to
assign custom identifier strings to the bar code
symbologies.
Code mark Enables the code mark symbology identifier for all
symbologies.