Chapter 4 — Configuration Command Reference
SR61 Cordless Scanner User’s Manual 55
With ISBN enabled, the first three characters (978) are ignored,
and the checksum is calculated on the remaining characters.
GTIN Processing
With Global Trade Item Number (GTIN) processing enabled,
two zeros are padded to the beginning of UPC-A, and one zero is
padded to the beginning of EAN-13 to expand the numbers to
14 digits. To use GTIN processing you also need to enable the
corresponding UPC/EAN symbology.
User Reset Factory Defaults
SR61xV (linear imager), SR61xA (area imager), and SR61xL
(laser scanner) only. Causes the SR61 to perform a restart and
restores all configuration commands to their default settings, only
if no settings are locked. To reset all settings on the SR61,
including locked settings, use the Administrator Reset Factory
Defaults command. For more information, see Administrator
Reset Factory Defaults” on page 39.
When you restore all configuration commands to their default
settings, you need to reestablish Bluetooth communications.
Vibrate Alert
Enables or disables the vibrate alert. When Vibrate Alert is
enabled, the scanner vibrates when you scan a valid bar code.
Vibrate Alert Duration
Sets the amount of time that the vibrate alert remains on. You can
set Vibrate Alert Duration to a value from 0 to 2550 ms.