Assembly and installation 
 
Version 3.0 (08/2018) 
Translation of original instruction manual    19 
5.3  Warning instructions for electrical installation 
Risk of injury when working on the electrical equipment 
➢  Electrical installation work should only be carried out by a qualified electrician. 
➢  Before installing, removing or connecting the MultiControl, disconnect the conveyor 
system from voltage and secure it against unintentional restart. 
➢  For any connections only use UL certified cable CYJV or PVVA. 
➢  Apply all the power supplies used to a common ground potential in order to avoid 
compensating currents via the MultiControl or the bus line. 
➢  Make sure all components are properly grounded. Improper grounding can lead to 
static charge, which may result in failure or premature failure of the MultiControl. 
➢  Provide suitable switching and protective devices that enable safe operation. 
➢  Only switch on the operating voltages when all lines are connected. 
Incorrect electrical installation can damage the MultiControl 
➢  Observe national regulations for electrical installation. 
➢  Only operate the MultiControl with 24 V protective extra low voltage (PELV). 
➢  Never operate the MultiControl with alternating current. 
➢  Pay attention to the correct polarity of the power supply. 
➢  Make sure that the existing electrical installation does not interfere with the 
MultiControl. 
➢  Only use cables that are sufficiently dimensioned for the specific operating 
conditions. 
➢  Consider calculations for voltage drop in electrical lines. 
➢  Observe the regulations for routing cables. 
➢  Do not expose plug to high tensile or compressive load. Bending the cable on the 
connector may damage the insulation of the cable and cause the MultiControl to 
fail.