Initial start up and operation
Version 3.0 (08/2018)
36 Translation of original instruction manual
Error - Settings
Network Error
Monitoring the communication between MultiControl and PLC:
Ignore: Error is not displayed.
Warning: Error is indicated by the fault LED flashing twice.
The conveying process is not interrupted.
Immediate Stop: Error is indicated by the fault LED flashing twice.
The conveying process is interrupted.
If the MultiControl is operated without PLC, we recommend the setting "Ignore".
If the MultiControl is operated with PLC, we recommend the setting "Immediate
Stop".
Over Voltage Error
Too high supply voltage:
Ignore: Error is not displayed.
Warning: Error is indicated by fault LED flashing six times.
The conveying process is not interrupted.
Immediate Stop: Error is indicated by fault LED flashing six times.
The conveying process is interrupted.

Table of Contents

Other manuals for Interroll MultiControl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interroll MultiControl and is the answer not in the manual?

Interroll MultiControl Specifications

General IconGeneral
Power Supply24 VDC
Rated Voltage24 VDC
Storage Temperature-20 °C to +70 °C
Communication ProtocolsEthernet/IP, PROFINET, EtherCAT, CANOpen
Number of Channels4
Weight0.5 kg