Initial start up and operation
Version 3.0 (08/2018)
44 Translation of original instruction manual
6.6 Operation
CAUTION
Danger of crushing due to unintentional starting of the RollerDrive
Before switching on the power supply, make sure that there are no persons in the
danger areas of the conveyor system.
If the MultiControl acts as an I / O device, it cannot automatically start or stop
motors or perform other actions. It requires commands from a higher-level controller,
e.g. a PLC.
Check before every start up
Check all MultiControl for visible damage.
Check all safety devices.
Ensure that no RollerDrive connected to the MultiControl is blocked.
Specify and monitor the laying of the conveyed material exactly.
Observe environmental conditions during operation (see "Technical Data", page 13)
Start
Ensure that the ambient conditions are observed during operation (see "Technical Data",
page 13).
Switch on the power supply.
Send the corresponding signal to the MultiControl.
Stop
The conveying process stops in the following cases:
If the power supply is switched off
If no signal is present for start
If an error from a corresponding error class is present (see "Error Settings", page 36)

Table of Contents

Other manuals for Interroll MultiControl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interroll MultiControl and is the answer not in the manual?

Interroll MultiControl Specifications

General IconGeneral
Power Supply24 VDC
Rated Voltage24 VDC
Storage Temperature-20 °C to +70 °C
Communication ProtocolsEthernet/IP, PROFINET, EtherCAT, CANOpen
Number of Channels4
Weight0.5 kg