Initial start up and operation
Version 3.0 (08/2018)
26 Translation of original instruction manual
6.3 User interface
The MultiControl has an integrated web server that generates a user interface for configuring the
MultiControl. This user interface can be called up via a computer connected to the MultiControl.
Except for a web browser, no additional software needs to be installed on the computer.
Requirements
To start the web-based user interface, the following requirements must be met:
• The MultiControl has a valid IP address which is known (factory setting: IP address
192.168.0.1, subnet mask 255.255.255.0).
• The connected computer must be in the same IP range (see system description / network
settings of the PC, if applicable).
• There is an Ethernet connection between the MultiControl and the computer.
• Access to port 80 is possible (user interface is HTTP-based).
• The MultiControl is not configured on EtherCAT because EtherCAT does not allow HTTP
communication. The bus type can be read out using the magnetic sensor (see
supplementary document "Interroll MultiControl - Operating and Programming").
Start the user interface
➢ On the computer connected to the MultiControl, start the web browser.
➢ Enter the IP address of the MultiControl in the address bar (factory setting:
http://192.168.0.1/).
➢ Enter the login data on the login page (factory setting: user name "Interroll", password
"Interroll").