Maintenance and cleaning
Version 3.0 (08/2018)
46 Translation of original instruction manual
7 Maintenance and cleaning
Risk of injury due to improper handling
➢ Maintenance and cleaning work should only be carried out by authorized and
instructed (specialist) personnel.
➢ Only carry out maintenance and cleaning work when de-energized. De-energize the
MultiControl and secure against unintentional restart.
➢ Set up signs indicating that maintenance or cleaning is in progress.
7.1 Maintenance
Check the MultiControl
The MultiControl itself is maintenance-free. However, to avoid interference, the connections and
fittings must be checked regularly.
➢ In the course of regular inspection and maintenance work on the conveyor, make sure that
the screws of the MultiControl are still tightened and the cables are still correctly routed
and connected to the corresponding connections.
Replace the MultiControl
If a MultiControl is damaged or defective, it must be replaced.
Do not try to open the MultiControl!
➢ Install a new MultiControl (see "Decommissioning", page 56 and "Assembling the
MultiControl", page 16).
➢ Configure new MultiControl (see "Initial Start up and operation", page 25).